Configure Digital Input To Reset DO

Configure Digital Input To Reset DO

Use a Digital Input to turn off a Digital Output configured using the Configure Digital Output from PMC command. See Send Digital Input to PMC

Fieldbus Interface

PMC_ConfigDI2Reset

Name

Data Type

Description

Name

Data Type

Description

Execute

BOOL

nDI

USINT

Number of digital inputs to configure, 1 to 22

DiID

USINT[0..21]

RstDoID

USINT[0..21]

, of digital output to reset (turn off)

PM_Controller

PMControllerType

Name

Data Type

Description

Name

Data Type

Description

Done

BOOL

Busy

BOOL

Aborted

BOOL

Error

BOOL

ErrorID

UINT

Conditions

Operating Conditions

Operating Conditions

Preconditions

None

Postconditions

Specified Digital Inputs is set to turn off the specified Digital Outputs

Description

Use a Digital Input to turn off a Digital Output configured using the Configure Digital Output from PMC command.

Event triggered Digital Outputs can only be turned off using this command. 

 

 