Read XBot Force
Read force data of a particular XBot.
Fieldbus Interface
PMC_ReadXbotForce
Conditions
Operating Conditions | |
---|---|
Preconditions | None |
Postconditions | XBot's force data is provided in the output. |
Description
This commands operates using a multiplexed response from the PMC to get new data. There is no buffer storage (to save precious PLC memory space), and so it may take more than 1 cycle to receive the response. You can still call the command multiple times in the same cycle. This means:
The age of the data (worst case) when calling this command is (cycle time)
The time it takes for the command (worst case) to provide a valid response is (cycle time * number of XBots)
A short cycle time is recommended for applications with a high number of XBots, in order to provide data in a reasonable time frame