PMC Fieldbus Cable CC-XXX-FB

PMC Fieldbus Cable CC-XXX-FB

 

image-20241210-230159.png
CC-XXX-FB cable

Technical Details

General Data

Cable Name

PMC Fieldbus Cable

Model Number

CC-XXX-FB,

XXX is 3-digit number code representing cable length with 020 for 2m, 050 for 5m, 100 for 10m, 200 for 20m.

Short Description

Fieldbus Cable

Long Description

Fieldbus cable, Ethernet CAT5 (100 Mbps), 4-position,

PUR halogen-free, water blue RAL 5021, shielded,

Plug straight M12 / IP67, coding: D, on Plug

Straight RJ45 / IP20, optional lengths of 2m, 5m, 10m, 20m.

Used for

Connection between Planar Motor Controller (PMC) and a host PC or PLC via a Fieldbus port

Dimensions

Length of Cable

2m, 5m, 10m, 20m.

Cable Weight

170 g for 2m, 350 g for 5m, 650 g for 10m, 1250 g for 20m

Ambient Conditions

Degree of Protection

IP67 (M12 connector)

Degree of Protection

IP20 (RJ45 connector)

Ambient Temperature (Operation)

-25 °C to 85 °C (M12 connector)

Ambient Temperature (Operation)

-25 °C to 60 °C (RJ45 connector)

Electrical/Signal Properties

Rated Current at 40°C

 1 A

Rated Voltage

48 V AC

Rated Voltage

60 V DC

Number of Positions

4

Signal Type/Category

Ethernet CAT5 (IEC 11801), 100 Mbps

Transmission Characteristics (Category)

CAT5

Transmission Speed

100 Mbps

Characteristics Head 1

Head Type

Male Plug straight M12 / IP67

Coding

D (Data)

Standards/Regulations

M12 connector IEC 61076-2-101

Contact Material

Cu-Sn

Contact Carrier Material

TPU GF

Contact Surface Material

Ni/Au

Housing Material

Plastic

Characteristics Head 2

Head Type

Plug straight RJ45 / IP20

Cable

Cable Type

Ethernet flexible CAT5, 2-pair

Cable Type (Abbreviation)

93E

UL AWM Style

20963 (80°C/30 V)

Signal Type/Category

Ethernet CAT5 (IEC 11801), 100 Mbps

Cable Structure

2x 2 x AWG26/7; SF/UTP

Conductor Cross Section

2x 2 x 0.14 mm²

AWG Signal Line

26

Conductor Structure Signal Line

7 x 0.16 mm

Core Diameter Including Insulation

0.98 mm

Wire Colours

white/orange-orange, white/green-green

Twisted Pairs

2 cores to the pair

Overall Twist

Two pairs with two fillers to the core

Shielding

Aluminium-coated foil, Tinned copper braided shield

Optical Shield Covering

70 %

External Sheath Colour

Water blue RAL 5021

Outer Sheath Thickness

1.2 mm

External Cable Diameter D

6.4 mm ±0.2 mm

Minimum Bending Radius, Fixed Installation

4 x D

Minimum Bending Radius, Flexible Installation

8 x D

Tensile Strength GRP

<= 80 N

Cable Weight

42 kg/km

Outer Sheath Material

PUR

Material Conductor Insulation

Foamed PE

Conductor Material

Bare Cu litz wires

Standards/Specifications

Electrical requirements EN 50288-2-2

Insulation Resistance

 500 MΩ *km

Loop Resistance

 290.00Ω /km

Cable Capacity

Approx. 45 nF/km (at 1 kHz)

Wave Impedance

100Ω  ±5Ω   (at 100 MHz)

Signal Runtime

5.3 ns/m

Coupling Resistance

 100.00mΩ/m  (at 10MHz)

Nominal Voltage Cable

100 V (Peak value, not for highpower applications)

Test Voltage Core/Core

700 V (50 Hz, 1 min.)

Test Voltage Core/Shield

700 V (50 Hz, 1 min.)

Current Carrying Capacity of Cable

2 A (according to DIN VDE 0891-1)

Flame Resistance

According to IEC 60332-1-2, UL VW1

Halogen-free

According to IEC 60754-1

Resistance to Oil

According to EN 60811-2-1

Shielded

Yes

Environmental Product Compliance

REACH SVHC

Lead 7439-92-1

China RoHS

Environmentally Friendly Use Period = 50 years

Schematic Diagram

Pin Assignment M12 Connector, 4-Pos., D-Coded

Circuit Diagram of M12 and RJ45 Plug

Pin Assignment RJ45 Plug

 

image-20241210-230602.png

 

 

image-20241210-230606.png

 

 

image-20241210-230611.png

 

 

Feedback and Comments