PMC Fieldbus Cable CC-XXX-FB
Technical Details
General Data | |
Cable Name | PMC Fieldbus Cable |
Model Number | CC-XXX-FB, XXX is 3-digit number code representing cable length with 020 for 2m, 050 for 5m, 100 for 10m, 200 for 20m. |
Short Description | Fieldbus Cable |
Long Description | Fieldbus cable, Ethernet CAT5 (100 Mbps), 4-position, PUR halogen-free, water blue RAL 5021, shielded, Plug straight M12 / IP67, coding: D, on Plug Straight RJ45 / IP20, optional lengths of 2m, 5m, 10m, 20m. |
Used for | Connection between Planar Motor Controller (PMC) and a host PC or PLC via a Fieldbus port |
Dimensions | |
Length of Cable | 2m, 5m, 10m, 20m. |
Cable Weight | 170 g for 2m, 350 g for 5m, 650 g for 10m, 1250 g for 20m |
Ambient Conditions | |
Degree of Protection | IP67 (M12 connector) |
Degree of Protection | IP20 (RJ45 connector) |
Ambient Temperature (Operation) | -25 °C to 85 °C (M12 connector) |
Ambient Temperature (Operation) | -25 °C to 60 °C (RJ45 connector) |
Electrical/Signal Properties | |
Rated Current at 40°C | 1 A |
Rated Voltage | 48 V AC |
Rated Voltage | 60 V DC |
Number of Positions | 4 |
Signal Type/Category | Ethernet CAT5 (IEC 11801), 100 Mbps |
Transmission Characteristics (Category) | CAT5 |
Transmission Speed | 100 Mbps |
Characteristics Head 1 | |
Head Type | Male Plug straight M12 / IP67 |
Coding | D (Data) |
Standards/Regulations | M12 connector IEC 61076-2-101 |
Contact Material | Cu-Sn |
Contact Carrier Material | TPU GF |
Contact Surface Material | Ni/Au |
Housing Material | Plastic |
Characteristics Head 2 | |
Head Type | Plug straight RJ45 / IP20 |
Cable | |
Cable Type | Ethernet flexible CAT5, 2-pair |
Cable Type (Abbreviation) | 93E |
UL AWM Style | 20963 (80°C/30 V) |
Signal Type/Category | Ethernet CAT5 (IEC 11801), 100 Mbps |
Cable Structure | 2x 2 x AWG26/7; SF/UTP |
Conductor Cross Section | 2x 2 x 0.14 mm² |
AWG Signal Line | 26 |
Conductor Structure Signal Line | 7 x 0.16 mm |
Core Diameter Including Insulation | 0.98 mm |
Wire Colours | white/orange-orange, white/green-green |
Twisted Pairs | 2 cores to the pair |
Overall Twist | Two pairs with two fillers to the core |
Shielding | Aluminium-coated foil, Tinned copper braided shield |
Optical Shield Covering | 70 % |
External Sheath Colour | Water blue RAL 5021 |
Outer Sheath Thickness | 1.2 mm |
External Cable Diameter D | 6.4 mm ±0.2 mm |
Minimum Bending Radius, Fixed Installation | 4 x D |
Minimum Bending Radius, Flexible Installation | 8 x D |
Tensile Strength GRP | <= 80 N |
Cable Weight | 42 kg/km |
Outer Sheath Material | PUR |
Material Conductor Insulation | Foamed PE |
Conductor Material | Bare Cu litz wires |
Standards/Specifications | Electrical requirements EN 50288-2-2 |
Insulation Resistance | 500 MΩ *km |
Loop Resistance | 290.00Ω /km |
Cable Capacity | Approx. 45 nF/km (at 1 kHz) |
Wave Impedance | 100Ω ±5Ω (at 100 MHz) |
Signal Runtime | 5.3 ns/m |
Coupling Resistance | 100.00mΩ/m (at 10MHz) |
Nominal Voltage Cable | 100 V (Peak value, not for highpower applications) |
Test Voltage Core/Core | 700 V (50 Hz, 1 min.) |
Test Voltage Core/Shield | 700 V (50 Hz, 1 min.) |
Current Carrying Capacity of Cable | 2 A (according to DIN VDE 0891-1) |
Flame Resistance | According to IEC 60332-1-2, UL VW1 |
Halogen-free | According to IEC 60754-1 |
Resistance to Oil | According to EN 60811-2-1 |
Shielded | Yes |
Environmental Product Compliance | |
REACH SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
Schematic Diagram
Pin Assignment M12 Connector, 4-Pos., D-Coded | Circuit Diagram of M12 and RJ45 Plug | Pin Assignment RJ45 Plug |
|
|
|
Feedback and Comments
Please email us at tech.portal@planarmotor.com